6024917


SICK (UE10-30S2D0) SAFETY RELAY (6024917)

Your cart total:

Discontinued

6024917






























Manufacturer:SICK
Model:UE10-30S2DO
Width (mm):22.5
Series:Safety Relays
Type of switching amplifier:Contract expansion module
Opto-electronic protective devices:Yes
Opto-electronic protective devices with RES/EDM:Yes
System part:Safety relays
Input circuit:Single or dual-channel
Reset/restart:Automatic
Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061)
Category:Category 4 (EN ISO 13849)
Performance level:PL e (EN ISO 13849)
B10d parameter:1.26 * 1E 06 switching cycles (AC-15, 230 V, I = 1.5 A), 5.9 * 1E 06 switching cycles (AC-15, 230 V, I = 0.75 A), 4.35 * 1E 05 switching cycles (DC-13, 24 V, I = 2.5 A),
1 * 1E 07 switching cycles (DC-13, 24 V, I = 0.63 A)
PFHd:3.0 * 1E-08
TM (mission time):20 a
Stop category:0, EN 60204
Contact type:Positively driven
Number of enable current contacts:3
Number of signalling current contacts:1
Rated operating current (voltage):4 A (230 V AC) 360 switching cycles/h, 3 A (230 V AC) 3600 switching cycles/h, 4 A (24 V DC) 360 switching cycles/h, 2.5 A (24 V DC) 3600 switching cycles/h
Maximum switching current:6 A
Maximum total current:12 A
Mechanical life (relay contacts):1 * 1E 07 switching cycles
Electrical life (relay contacts):2 * 1E 06 switching cycles, dependent upon loading, details see operating instructions
Enclosure rating:IP 20
Ambient operating temperature from … to:-25 °C … 55 °C
Connection type:Screw-type terminals

No extended details available.